RX-4035SA (SPI-Bus Real Time Clock Module)

  • Built in 32.768 kHz crystal unit
    Frequency adjusted for high accuracy.
    (±5x10-6/Ta=+25°C)
  • Interface Type
    SPI-Bus (1MHz)
  • Operating voltage range
    2.4V to 5.5V
  • Timekeeping voltage range
    1.0V to 5.5V
  • Low backup current
    350nA(SA) 400nA(LC)/ 3V(Typ.)
  • Event detection and Time stamp
    One-shot full timestamp and interrupt.
  • Dual event detection ports
    Each terminal has a de-bounce circuit.
  • Auto power switching functions
    When VDD deteriorates than 2.4V,internal source is switched to VBAT.

Complies with EU RoHS directive.

RX-4035SA
RX-4035SA

Block diagram

Block diagram

Overview

  • The event detection and Timestamp function
    • Dual event detection terminals.
    • Selectable de-bounce period 35ms or 2s.
    • Available event detection interrupt output.
  • Power switching functions.
    • When VDD is less than 2.4V, an internal source is switched to VBAT.
    • Note: When the supply from VBAT, SPI interface are disabled.
  • Alarm, Periodic interrupt, 32.768kHz clock output.
    • Available monthly-alarm and weekly-alarm.
    • Interrupt period are selectable from 2Hz to Monthly.
    • CLKOUT outputs 32.768kHz clock powered by VDD.

Specifications (characteristics) *Refer to application manual for details.

Recommend Operating Conditions

Item Symbol Conditions Min. Typ. Max. Unit
Operating voltage VACCESS VDD 2.4 3.0 5.5 V
Time keeping voltage VCLK VBAT 1.0 3.0 5.5 V
Operating temperature TOPR - -40 +25 +85 °C
Storage temperature TSTG - -55 - +125 °C

Frequency characteristics

Item Symbol Conditions Rating Unit
Frequency tolerance Δ f/f Ta=+25°C VBAT=3.0V B: 5±23 *1)
AA: 5±5 *2)
AC: 0±5 *2)
×10-6
Oscillation start-up time tSTA Ta=+25°C VDD=3.0V 1 Max. s
Frequency/voltage characteristics f/V Ta = +25°C VDD=2.4V to 5.5V ±1 Max. ×10-6

*1) Equivalent to ±1 minute of monthly deviation (excluding offset.)
*2) Equivalent to ±13 seconds of monthly deviation (excluding offset.)

Current consumption characteristics

Ta=-40°C to +85°C

Item Symbol Conditions Min. Typ. Max. Unit
Current Consumption lBAT RX-4035SA
VBAT=3.0V, VDD=0.0V CE=0V, CLKOUT=open
- 350 1200 nA
IDD VDD=3.0V CE=0V CLKOUT=open - 1.40 2.50 µA

Power supply detection voltage

Ta=-40°C to +85°C

Item Symbol Condition Min. Typ. Max. Unit
VBAT detect voltage VLOW - 1.10 1.25 1.40 V
Power switching voltage
(VDD to VBAT)
VD2B +25°C 2.328 2.40 2.472 V

name

Pin function

Signal Name Input/Output Functions
VBAT - Power supply for backup.
Vout Output Switched power out.(maximum output current 20mA)
CE Input SPI chip enable.
CLK Input SPI serial clock.
SO Input SPI data out.
SI Input SPI data in.
GND - Ground
EVIN1 Input Event detection input 1
EVIN2 Input Event detection input 2
/ INT Output Interrupt out.
CLKOUT Output 32.768kHz output. (CMOS. Can not inhibit.)
N.C. - Do not connect.
VDD - Main power supply.

Terminal connection / External dimensions

Terminal connection External dimensions

(Unit: mm)

The metal case inside of the molding compound may be exposed on the top or bottom of this product.
This purely cosmetic and does not have any effect on quality, reliability or electrical specs.

Footprint (Recommended)

footprint

(Unit: mm)

To maintain stable operation, provide a 0.1uF by-pass capacitor
at a location as near as possible to the power source terminal of the crystal product (between Vcc - GND).

Page Top