VG5032EDN (VOLTAGE-CONTROLLED CRYSTAL OSCILLATOR (VCXO))
Output:LV-PECL
- Frequency range
85 MHz to 170 MHz
- Supply voltage
3.3 V Typ.
- Absolute pull range
50 × 10-6 Min.
- External dimensions
5.0 × 3.2 × 1.3 t (mm) Typ.
- Operation temperature
-40°C to +85°C / -40°C to +105°C
- Function
Output Enable(OE), Active High
- Output
LV-PECL
(High-Frequency Fundamental)
Specifications
Item | Symbol | VG5032EDN (LV-PCLE) |
VG5032VDN (LVDS) |
Conditions / Remarks | |
---|---|---|---|---|---|
Output frequency range | f0 | 85 MHz to 170 MHz | Please contact us for inquiries regarding available frequencies. | ||
Supply voltage | VCC | 3.3V ±0.165V | |||
Storage temperature | T_stg | -55°C ~ +125°C | Store as bare product. | ||
Operating temperature | T_use | G: -40°C to +85°C H: -40°C to +105°C |
|||
Frequency tolerance | f_tol | ±50 × 10-6 Max. | Includes initial tolerance, temperature change, Vcc change and 10years aging at +25°C. At Vc=1.65V, reference to f0 | ||
Absolute Pull range *1 | APR | ±50×10-6 Min. | VC= 1.65V ±1.65V | ||
Input resistance | Rin | 10MΩ Min. | DC level | ||
Current consumption | ICC | 60mA Max. | 30mA Max. | OE=Vcc, LV-PECL: 50Ω, LVDS: 100 Ω | |
Symmetry | SYM | 45% ~55% | LV-PECL: at Vcc-1.30 V, VC=1/2Vcc LVDS: at outputs crossing point |
||
Output voltage | VOH | VCC-1.1V Min. | ― | LV-PECL: DCcharacteristics | |
VOL | VCC-1.5V Min. | ― | |||
VOD | ― | 250 mV to 450mV | VOD1, VOD2 | LVDS: DCcharacteristics | |
VOS | ― | 1.15 V to 1.35 V | VOS1, VOS2 | ||
Output load condition |
L_ECL | 50 Ω | ― | LV-PECL: Terminated to VCC -2.0 V | |
L_LVDS | ― | 100 Ω | LVDS: Connected between OUT1 to OUT2 | ||
Input voltage | VIH | 70 % Vcc Min. | OE terminal | ||
VIL | 30 % Vcc Max. | ||||
Rise time / Fall time | tr / tf | 0.5 ns Max. | LVP-ECL: at 20 % to 80 % output swing | ||
0.3 ns Max. | LVDS: at 20 % and 80 %of Differential Output peek to peek voltage | ||||
Start-up time | t_str | 10 ms Max. | Time at minimum supply voltage to be 0 s | ||
Phase Jitter | tPJ | 0.3 ps Typ. | Offset Frequency 12kHz to 20MHz |
*1 Absolute pull range = Frequency control range- Frequency tolerance
* Please keep VC pin open or ground while powering up Vcc
External dimensions
(Unit: mm)
Footprint (Recommended)
(Unit: mm)